8 External Voltage Sequence Trigger– TheETA-ECS3canbeactivatedremotelybyprovidingDCvoltagesbetween5VDCand
24VDC.Note:ThisfunctionoverridesthefrontpanelSystemActivationSwitch.
9. External Sequence Trigger– TheETA-ECS3canbeactivatedremotelybyplacingamomentaryswitchbetweenthetwocontact
points.Note:ThisfunctionisinparallelwiththefrontpanelSystemActivationSwitch.
10. ETA-ECM20 DCV trigger– TheETA-ECS3canhandle15Aofcurrentbeforethebreakeropens.If15Aisnotenoughcurrent
tosupportthepowerrequirements,thisoutputcanbeusedtoactivateanadditionalpoweroutletsuchastheETA-20SH.This
triggered24VDCvoltageworksinconjunctionwithSequence3timingsection.ContactETASystemsforACoutletoptions.
ETA-ECS3
Power Sequencer & Conditioner