Vue de la page 0
Leica EG1150 H
Paraffin Embedding
Station
Instruction Manual
Leica EG1150H
V2.0 English - 10/2002
Always keep this manual near the instrument.
Read carefully prior to operating the instrument.
Vue de la page 0
1 2 3 4 5 6 ... 37 38

Résumé du contenu

Page 1 - Leica EG1150 H

Leica EG1150 HParaffin EmbeddingStationInstruction ManualLeica EG1150HV2.0 English - 10/2002Always keep this manual near the instrument.Read carefully

Page 2

10Instruction Manual V 2.0  10/20023.2 Overview  instrument parts3. Instrument components and specificationsFig. 1Paraffin reservoirwith lidCassette

Page 3

11Leica EG1150 H  Paraffin Embedding Station3. Instrument components and specifications3.3 Instrument specifications Paraffin reservoir with a capac

Page 4 - Table of contents

12Instruction Manual V 2.0  10/2002 To lift up the instrument (6), hold it at thefront and rear of the base plate (Fig. 4) andlift it from the foam

Page 5 - 1. Important notes

13Leica EG1150H  Paraffin Embedding Station4. Commissioning4.2 Location conditions Stable, vibration-free laboratory table with horizontal, flat tab

Page 6 - 2. Safety

14Instruction Manual V 2.0  10/20024. Commissioning4.4 Necessary assembly workInstall the following accessories and make the appropriate adjustments

Page 7

15Leica EG1150 H  Paraffin Embedding Station4. CommissioningInstalling the accessories12345678910Fig. 511116

Page 8

16Instruction Manual V 2.0  10/20024. Commissioning4.5 Optional accessoriesMagnifying glassThe magnifying glass provides a magnified view of the work

Page 9 - 3.1 Specifications

17Leica EG1150H  Paraffin Embedding Station4.6 Electrical connectionThe instrument MUST be connected to a grounded mains socket.The instrument is sup

Page 10

18Instruction Manual V 2.0  10/20025.1 Instrument parts/functionsParaffin reservoir (1)The paraffin reservoir has a capacity of 3 liters.The paraffin

Page 11 - 3.3 Instrument specifications

19Leica EG1150H  Paraffin Embedding StationWork area (3)The temperature of the work area can be ad-justed between 55 °C and 70 °C in 5 degree(K) incr

Page 13

20Instruction Manual V 2.0  10/2002Paraffin collection tray (8)Two indirectly-heated paraffin collectiontrays for excess paraffin are located unde

Page 14

21Leica EG1150H  Paraffin Embedding StationWork area illumination (9)A halogen lamp provides homogeneous dif-fuse illumination of the embedding area

Page 15

22Instruction Manual V 2.0  10/2002The foot switch (22) actuates the magnetvalve of the dispenser.It must be connected as described inChapter 4.6.The

Page 16

23Leica EG1150 H  Paraffin Embedding Station5.2 Switching the instrument on Activate the standby switch (left-hand side, next to control panel) (see

Page 17

24Instruction Manual V 2.0  10/20025. Operation5.3 Control panel functions1 - Cassette/mold warmer, left2 - Paraffin reservoir and dispenser3 - Work

Page 18 - 5. Operation

25Leica EG1150 H  Paraffin Embedding Station5. Operation5.4 Operating modesStandby modeThe display and all LEDs are switched off in standby mode. The

Page 19

26Instruction Manual V 2.0  10/20025. Operation5.5 Time-program controlThe value shown in the display must be set to the current local time to en-sur

Page 20

27Leica EG1150 H  Paraffin Embedding StationWeekdays/working daysThe automatic switch-on feature is linked with the individual weekdays. Itis therefo

Page 21

28Instruction Manual V 2.0  10/20025. OperationIndication of the heating intervalsIn the temperature range indication field, the LED for the temperat

Page 22

29Leica EG1150H  Paraffin Embedding Station5. OperationEnhanced modeA large amount of heat is needed for melting paraffin. This is only ac-counted fo

Page 23

3Leica EG1150H  Paraffin Embedding StationThe information, numerical data, notes and valuejudgments contained in this manual represent thecurrent sta

Page 24

30Instruction Manual V 2.0  10/2002Do not use xylene for cleaning. Xylene vapors are heavier than air and can ignite at aconsiderable distance from t

Page 25

31Leica EG1150 H  Paraffin Embedding StationParaffin collection tray Before the paraffin collection tray drawers can be emptied, any excess paraffin

Page 26

32Instruction Manual V 2.0  10/20027. TroubleshootingPossible causeProblem- This is not an errormessage!The instrument will switchto the program mode

Page 27

33Leica EG1150 H  Paraffin Embedding Station7. TroubleshootingPossible causeProblem Corrective action3. Paraffin reservoirParaffin does not melt orme

Page 28

34Instruction Manual V 2.0  10/20027. TroubleshootingPossible causeProblem Corrective action6. Individual heated areas(despite correct tempera-ture i

Page 29

35Leica EG1150 H  Paraffin Embedding Station7. Troubleshooting7.2 Replacing the halogen lampOnly use the original replacement lamp delivered with the

Page 30 - 6. Cleaning and maintenance

36Instruction Manual V 2.0  10/20027. Troubleshooting7.3 Changing a fuseBefore changing a fuse switch the instrument off and pull out the mains plug.

Page 31

37Leica EG1150H  Paraffin Embedding Station7. TroubleshootingOn the back there are five dif-ferent fuse holders (Fig. 24).One spare fuse must be se-l

Page 32 - 7. Troubleshooting

38Instruction Manual V 2.0  10/20028. Warranty and serviceWarrantyLeica Microsystems Nussloch GmbH guarantees that the contractualproduct delivered h

Page 33

4Instruction Manual V 2.0  10/2002Table of contents1. Important notes ...

Page 34

5Leica EG1150H  Paraffin Embedding Station1.1 Symbols used in the text and theirmeaningsWarnings and cautionsappear in a gray box and are markedby a

Page 35

6Instruction Manual V 2.0  10/20022. Safety2.1 Safety regulationsThis instruction manual contains important in-structions and information regarding o

Page 36

7Leica EG1150 H  Paraffin Embedding Station2. SafetySafety instructions  safety regulations on the instrument itselfSafety regulations marked with a

Page 37

8Instruction Manual V 2.0  10/20022. SafetyHazards  servicing and cleaningSwitch off the instrument each time before servicing and pull out the main

Page 38 - 8. Warranty and service

9Leica EG1150 H  Paraffin Embedding Station3. Instrument components and specifications3.1 SpecificationsGeneral dataApprovals: The approval symbols r

Commentaires sur ces manuels

Pas de commentaire